Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Acta Medica Philippina ; : 616-620, 2021.
Article in English | WPRIM | ID: wpr-987817

ABSTRACT

Objectives@#Shift work results in changing worker’s behavior, food, and sleep patterns, which can cause circadian rhythm disturbance, which is a cardiovascular risk. Until now, a biomarker of early prediction of cardiovascular risk on shift workers is still not developed. This study aimed to assess the cardiovascular risk of shift worker nurses by detecting endothelial microparticles (EMPs). @*Methods@#This longitudinal study compared six shift nurses and five non-shift nurses by measuring the EMPs using antigen CD31+ flow cytometry. All met the inclusion criteria consisting of 28 blood samples followed in one week shift. @*Results@#EMPs among non-shift nurses were below 200 μL. However, shift nurses’ EMPs increased above 200 μL with Man-Whitney U p = 0.000 on days 4 and 7 following a one shift per week schedule. @*Conclusion@#There was an increase in shift workers’ endothelial microparticles (EMP) which was a sign of cardio-vascular risk.


Subject(s)
Heart Disease Risk Factors , Nurses
2.
Pediatric Gastroenterology, Hepatology & Nutrition ; : 388-396, 2020.
Article | WPRIM | ID: wpr-834125

ABSTRACT

Purpose@#Impaired intestinal mucosal integrity may affect the gastrointestinal function, especially in relation to nutrition, absorption, and barrier function. The purpose of this study was to measure the prevalence of impaired intestinal mucosal integrity in presumed healthy children aged 1–3 years and assess the effects of zinc, glutamine, fiber, and prebiotic supplementation in them. @*Methods@#A cross-sectional study was conducted in 200 children aged 1–3 years in Pasar Minggu, South Jakarta, Indonesia. A randomized double-blind parallel group method clinical trial was then performed to assess the effects of zinc, glutamine, fiber, and prebiotic supplementation. @*Results@#Elevated calprotectin was found in 91/200 subjects (45.5%) at the onset of the study. After 10 months, 144 subjects completed the study: 72 subjects received the trial formula, whereas the other 72 received the standard formula. A transitory decrease in fecal calprotectin (FC) was observed after 6 months in the subgroup with normal FC levels, who were fed the test formula (p=0.012). @*Conclusion@#The prevalence of impaired intestinal mucosal integrity in this group of Indonesian children aged 1–3 years was high. Supplementation with zinc, glutamine, fiber, and prebiotics during 6 months reduced FC only in those who had low levels at baseline but not in those with impaired integrity.

3.
Journal of Laboratory Medicine and Quality Assurance ; : 231-235, 2003.
Article in English | WPRIM | ID: wpr-119814

ABSTRACT

BACKGROUND: Ethanol gelation test (EGT) is one of the paracoagulation test used to detect the activation of coagulation and formation of fibrin monomer complexes in the fibrinolytic process. Many patients with infectious diseases such as dengue haemorrhagic fever can develop disseminated intravacular coagulation (DIC), which should be diagnosed properly as soon as possible for the management of the patients. To diagnose the coagulation activation and DIC usually the laboratory has to perform the coagulation test, including fibrinopeptide A and D-dimer test. Many laboratories in rural areas in Indonesia do not have the facilities to do such test, and the cost will not be affordable by most of the patients. The aim for the study is to evaluate the EGT as a screening test to detect coagulation activation and DIC, the correlation of D-dimer and EGT. Method: Sixty citrated plasma were obtained from patients in Clinical Pathology Laboratory Cipto Mangunkusumo Hospital for D-dimer test. D-dimer were performed using Nycard Kit with cut off point of 300 ng/dl. The EGT were performed using the method described by Breen. Positive test could be observed by the clot formation. RESULTS: The result of the within-run test for normal and abnormal plasma for EGT showed good results. The plasma was stalell until day 22. The EGT was positive for all the plasma with D-dimer >700 ng/ml. The sensitivity for EGT was 81.6%, specificity 81.8%, positive predictive value 95.2% and negative predictive value 50%. Conclusion: EGT could be used as a screening test for thrombin activity in coagulation activation in rural laboratories with minimal facilities.


Subject(s)
Humans , Communicable Diseases , Dacarbazine , Dengue , Disseminated Intravascular Coagulation , Ethanol , Fever , Fibrin , Fibrinopeptide A , Indonesia , Mass Screening , Pathology, Clinical , Plasma , Sensitivity and Specificity , Thrombin
4.
Journal of Laboratory Medicine and Quality Assurance ; : 237-242, 2003.
Article in English | WPRIM | ID: wpr-119813

ABSTRACT

BACKGROUND: Infection is still a major problem in developing countries, including Indonesia. The incidence of neonatal infection in some referral hospital in Indonesia is quite high, between 8.76-30.29%, with a mortality rate of 11.56-49.9%. The early detection of neonatal sepsis is very important for the management of the patients, but many rural health centers do not have the required laboratory facilities available to diagnose it. The ratio of immature neutrophyl to total neutrophyl (IT ratio) is a simple test, requiring no sophisticated equipment, and can be done in a minimal laboratory setting to be used as a screening test to detect infection. In infection or sepsis a shift to the left of the neutrophil in the peripheral blood smear could be observed. An IT ratio of >0.2 and leukopenia is a marker for detecting neonatal infection. The aim of this study is to obtain the reference value of IT ratio in healthy newborn children and to know the IT ratio in neonatal sepsis and the difference of IT ratio of between capillary and K3EDTA blood. Blood smears were also made hourly with K3EDTA blood kept for 6 hours to observe any changes. METHODS: Materials were obtained from 70 healthy and 41 septic newborns. Capillary blood smear and K3EDTA blood smear were prepared using May-Grunwald-Giemsa staining, and a differential counts were performed manually using a binocular microscope. RESULTS: Reference IT Ratio in healthy newborns was 0.01-0.13 (mean 0.06), in septic newborns 0.13-0.60 (mean 0.26) and the cut off value for sepsis detection was 0.13. There were no difference in the IT ratio between direct capillary blood or K3EDTA blood smear. Samples could be kept until 6 hour without any deterioration. CONCLUSION: The reference value of IT ratio in healthy newborns were 0.01-0.13 (mean 0.06), in sepsis neonatus 0.13-0.60 (median 0.26) and the cut off value for sepsis detection was 0.13. IT ratio could be used as a marker for early detection of newborn septicemia.


Subject(s)
Child , Humans , Infant, Newborn , Capillaries , Developing Countries , Incidence , Indonesia , Leukopenia , Mass Screening , Mortality , Neutrophils , Reference Values , Referral and Consultation , Rural Health Services , Sepsis , Telescopes
SELECTION OF CITATIONS
SEARCH DETAIL